Pressure Drainage System "Sanipump Series"

Toilets, washbasins, and mini kitchens can be installed in places where drainage slopes cannot be achieved! Increased design flexibility for water-related areas.

The "Sanipump" is a pump-assisted drainage system that allows for the installation of water facilities in places where "it is difficult to achieve drainage gradients" and "the distance from the shared vertical pipe is far." It can easily meet needs such as wanting a toilet in the basement or adding a toilet, washbasin, or mini kitchen near the bedroom of an elderly person. It is also possible to install refrigerated showcases in places where drainage is not possible. You are freed from the constraints of drainage gradients, greatly increasing design flexibility! 【We also offer our "original options" alarm devices!】  ◎ Remote pressure detection "SaniSensor" (for SaniSpeed Plus and SaniAccess 3)  ◎ Electrode type "Electrode Rod (nickname: Amenbo)" (for SaniCubic) Both detect abnormal water levels and send signals to the alarm panel. 【Examples of installation】 ■ Buildings ■ Commercial facilities ■ Hospitals and clinics ■ Supermarkets and convenience stores ■ Train stations and in-station stores ■ Factories ■ Residential areas on slopes ■ Underground of apartments … and more, products can be selected according to usage and installation conditions. *For more details, please refer to the catalog. Feel free to contact us with any inquiries.

  • ※P70406.jpg
  • IMG1.jpg
  • P550.jpg
  • scb.jpg
  • IMG1763.jpg
  • IMG3.jpg
  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pressure Drainage System Sanispeed Plus [Equipped with New Features]

The Sanispeed has undergone a model change! It's perfect for drainage in convenience stores, station shops, and commercial facilities. The new features make installation easier.

The pressure drainage system, Sanispeed Plus, has undergone a model change! By lowering the activation water level compared to the previous model, it has become possible to keep the height of horizontal piping, such as showcase drain drainage installed in convenience stores, station shops, and commercial facilities, lower, making installation easier. The application has also expanded to drainage fixtures with a low "overflow edge." Case studies are also available for viewing! *For more details, please download the PDF or contact us.

  • pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pressure drainage system "Sanispeed Plus" *Case study collection available!

The startup water level is lowered, making construction easier! Installing toilets and washbasins in the building and basement floors.

The pressure-assisted drainage system "Sanispeed" allows for the installation of water facilities even in places where "it is difficult to achieve drainage slope" and "the distance from the shared vertical pipe is far." In the model-changed 'Sanispeed Plus,' the lower starting water level enables the height of the horizontal piping to be kept low. This makes installation easier and is effective not only in convenience stores, station shops, and commercial facilities but also in nursing homes, childcare facilities, and medical institutions. ★ We are currently offering a "Construction Case Collection" summarizing examples for public and commercial facilities! You can view it immediately from the [Download] link. 【Construction Examples (partial)】 ■ Installation of toilets, handwashing sinks, and mini sinks in a clinic within an office building ■ Installation of outdoor toilet units at an experiential farm ■ Water facility equipment demonstration at an exhibition booth ■ New installation of a toddler handwashing machine in a nursery within a tenant building, etc. * For more details, please refer to the materials. Feel free to contact us as well.

  • ponnpu.jpg
  • Drainage and ventilation equipment
  • Washbasin, hand washing basin, sink
  • Outdoor toilet unit

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Silent Vacuum Drainage System

The Silent Vacuum Drainage System solves your drainage problems!

The Silent Vacuum Drainage System is... When installing toilets or similar facilities in a basement, it is common to have a sewage tank and use a sewage pump for a pressurized system. However, a minimal amount of sewage often remains in the tank, leading to unpleasant odors. Additionally, when trying to install toilets or water facilities in existing buildings, it can be difficult to ensure proper usage conditions and the slope of the drainage pipes on lower floors, which may lead to abandonment of the project. To address these issues, a vacuum-based drainage system has been devised as an alternative to the pressurized system. However, many systems apply a vacuum sewage system that uses lift-up support and gas-liquid mixed suction, which has caused problems with noise and vibration. This system is a Silent Vacuum Drainage System that resolves noise and vibration issues by using a method that does not involve air suction. Model demonstrations are available for viewing. Please feel free to contact us.

  • 写真1.jpg
  • 写真2.png
  • 写真3.jpg
  • 真空.jpg
  • Unit Products
  • pump
  • Drainage and ventilation equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Introduction of case studies for the Silent Vacuum Drainage System (2)

Even if there are no drainage pipes nearby and the piping route is uneven, drainage is still possible! (At a certain station building)

**Renovation Case at a Certain Station (Shizuoka Prefecture)** (1) Requirements We wanted to drain the station office, platform shop, and restaurant, but there were no drainage pipes nearby. (2) Specific Reasons for Hindrance to Requirements The drainage pipe route to connect to the drainage pipe was uneven, making it impossible to use a pump-up system. (3) Specific Design We adopted an SVD system to suction drainage to the platform with a drainage pipe. ▼ Vacuum Unit - System Decision Due to space constraints, we adopted the non-continuous suction I-2 type vacuum unit. - Installation Location Decision Installed on the existing drainage pipe platform with a fenced enclosure. ▼ Vacuum Pipeline - Route Decision The installation route was planned only through the uneven piping route under the train tracks. - Vacuum Tube Consideration A vacuum tube (pipe) was installed independently from the vacuum unit. ▼ Detection Pit - Installation Location Decision Station Office: 450×450×400H Platform Shop: 350×350×350H Restaurant: 350×450×550H - Capacity Consideration Since there is one vacuum collection tank, we planned the suction water level and alarm water level to ensure no disruption to drainage even when the system is stopped.

  • 00.png
  • jirei2-1.png
  • jirei2-2.png
  • jirei2-3.png
  • jirei2-4.png
  • jirei2-5.png
  • jirei2-6.png
  • jirei2_0-1.png
  • jirei2_0-2.png
  • Unit Products
  • pump
  • Drainage and ventilation equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Introduction of case studies for the Silent Vacuum Drainage System (3)

No need to secure pipe slope, making long-distance drainage possible! (Inside a certain station)

**Example of Renovation at a Certain Station (Kanagawa Prefecture)** (1) Requirements We want to remove the standalone treatment septic tanks that process wastewater from two facilities within the station and discharge directly into the public sewer. (2) Specific Reasons for Hindrance to Requirements The inflow pipe to the standalone treatment septic tank is too low, making it impossible to secure the necessary slope for discharging into the public sewer located about 150 meters away. Additionally, redoing the outdoor piping would require extensive earthworks, resulting in high construction costs. (3) Specific Design We adopted the SVD system and implemented above-ground piping without any earthworks, except for the detection chamber. ▼ Vacuum Unit - System Decision Considering cost-effectiveness and installation location, we chose the I-2 type. - Installation Location Decision Outdoor installation close to the public sewer. ▼ Vacuum Pipeline - Route Decision Piping laid above ground along the boundary fence of the property. - Vacuum Tube Consideration Since uneven piping was anticipated, it was planned independently from the vacuum unit. ▼ Detection Chamber - Installation Location Decision Installed in the space after the removal of each facility's standalone treatment tank. - Capacity Consideration To ensure a wastewater inflow of 100 liters during a system downtime of approximately 2 minutes, a height of 0.5 meters was secured between the suction water level and the alarm water level.

  • 00.png
  • jirei3-2.png
  • jirei3-3.png
  • jirei3-4.png
  • jirei3_0-1.png
  • jirei3_0-2.png
  • Unit Products
  • pump
  • Drainage and ventilation equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Relocation and expansion of water facilities with the "Sanipump Series" and "SVD".

Do you have concerns about not being able to relocate or add to your water facilities due to the need for drainage slope?

Introducing the Sanipump Series (Compact Pressure Drainage System) and SVD (Silent Vacuum Drainage System). Do you have any of the following concerns? - Want to add a gym but can't create a shower room... - Unable to install a toilet near the beds in a nursing facility and had to give up... - Complaints arose due to odors from temporary toilets during construction... - Relocating water facilities requires floor demolition work... Using a system that does not require a slope can solve these issues. ■ Sanipump Series This is a system that 'pressurizes' drainage using the power of a pump. We offer a wide range of products suitable for general drainage, sewage, and even commercial facility applications. ■ SVD (Silent Vacuum Drainage System) This is a system that uses 'vacuum' power to suction drainage. It can accommodate multiple fixtures and large capacities, and does not require power on the drainage fixture side. By using a method that does not suck in air, it also resolves noise and vibration issues. Of course, it is also possible to combine these two products. For more details, please download the materials or feel free to contact us.

  • ※SSP.jpg
  • ※SCUB.jpg
  • 写真.jpg
  • 真空.jpg
  • Unit Products
  • Special Construction Method
  • Commercial kitchen

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration